ZASLON OP-40

RADIOWAVE SINGLE MODE DETECTION DEVICE


sredstvo_obnaruzheniya_zaslon_op-404-01.jpg

Goal


Radiowave single mode detection device "Zaslon-OP-40" is designed as an alarm system for open areas or in facilities for detecting intruder movement in the detection area (DA).


Method


Is based on Doppler effect with the change in frequency of the radio waves reflected from the moving object. The size of the moving object determines the intensity of the reflected wave that allows to ignore small animals. The device generates a “curtain” detection area and is recommended for roofs, walls, etc.

Средство формирует зону обнаружения типа «штора» и рекомендуется его использование для охраны крыш, стен зданий и т.п.


АПП.jpg

DA view in two planes at max distance

Минимальная ширина ЗО (диаграммы излучения) – в плоскости, параллельной оси корпуса.

DA size adjustment is available.


Advantages


  • Consistent sensitivity throughout the operational area, a signal occurs with human movement in the DA remains the same at both min and max distance. A small animal signal moving close to the device (at 3 m distance where DA touches the ground) will be significantly less than the signal of a human being moving in the area at a distance of 40 m from the detector that allows to exclude false positive with small animals when the device is properly adjusted.


  • «Curtain» and «flat square» mode.

«Curtain» vertical detection area is applies to protection of fences, walls, gates installation areas.

«Flat square» detection area is designed for human detection moving in DA in the direction perpendicular to the direction of radiation, and provides some great noise immunity to short duration signal.


  • The device is interference-resistant to:


  - single small animals or birds movement in DA, the size of no more than a cat;

  - truck movement parallel to the axis of the DA at a distance of more than 2 m from the axis («curtain» mode) with a DA max length;


  - human movement parallel to the axis of the DA at a distance of more than 1 m from the axis («curtain» mode) with a DA max length.


  - a truck movement perpendicular to the axis of DA at a distance exceeding the established range to 75%.


  - lightning impulses with a peak value of the induced current up to 50 and up to 1ms;


  - VHF range 433 1 Mh and cellular phone at a distance of more than 0.5 m from the receiver.


  • Automatic and remote control panels, sabotage protection by shielding radiation subjects in the "dead" area are available.


  • The device is secured against reverse polarity supply voltage due to personnel mishap.


  • Dust and splash –resistance design of the device body.


  • A side-by-side devices installation is allowed with 2m min distance between.


Parameters


Option

Value

The range of detectable human speed, m/s

0,1 – 8

The DA max length , m, not less than

40

The max width of the DA in the plane perpendicular to the axis of the body (max distance), m, not more than

1

The DA max length , m, not less than

12

At maх distance, m, not more than

12

Range of operating voltages, V

10, 2-30

Consumed current, MA, not more than

270

Readiness time after power, sec, less than

60

The parameters of output circuit:

-current, constant or variable, MA, lea than

-the amplitude of voltage, less than


100

72

Remote control signal parameters:

-current consumed by a chain, MA,less than

-voltage pulse in;

-pulse duration, not less


5

5-30

0,4

Duration of alarm signal, sec, not less

2

Working frequency, MHz

24150± 100

Output power , w, no more

0,001

Transmitter dimensions with arm and with side visor mm, not more than

90х95х302

Packing weight, kg, not more

1,5

Average service life, years, not less

8

MTBF, h, not less

60000